Allied Vision Technologies Canada Inc. 101-3750 North Fraser Way Burnaby, BC V5J 5E9 / Canada GE1050 / GE1050C Technical Man
GE1050 Technical Manual Page 10 Item 1: GIGABIT ETHERNET PORT This port conforms to the IEEE 802.3 1000BASE-T standard for Gigabit Ethernet over cop
GE1050 Technical Manual Page 11 Sync Out 2 and Sync Out 3 These signals only function as outputs and can be configured as follows: Exposing Corres
GE1050 Technical Manual Page 12 Item 4: Mini-SMB Sync Out 1 This Mini-SMB port on the camera uses an Amphenol 903-406J-51R connector. A suitable ma
GE1050 Technical Manual Page 13 Item 7: AUXILIARY POWER PORT This port is required to provide power to the camera. This port provides threaded capti
GE1050 Technical Manual Page 14 Cleaning the Sensor DO NOT CONTACT CLEAN SENSOR UNLESS ABSOLUTELY NECESSARY. Identifying Debris Debris on the image
GE1050 Technical Manual Page 15 Adjusting the C-mount LOCKING RINGC MOUNT RING Figure 4. Camera Front View. THE C-MOUNT IS ADJUSTED AT THE FACTO
GE1050 Technical Manual Page 16 Camera Installation Computer Interface The Prosilica GE Series cameras will work with any Gigabit Ethernet network c
GE1050 Technical Manual Page 17 Gigabit Ethernet Setup for Windows o Install network card in computer. o Boot the PC and cancel the “Found new Ha
GE1050 Technical Manual Page 18 Figure 6. Network card TCP/IP address. Figure 7. Turn off Firewall. o Return to the Gige Local Properties win
GE1050 Technical Manual Page 19 Gigabit Ethernet Cabling All Gigabit Ethernet cabling and connectors should be CAT5E or CAT6 compatible. Cable leng
GE1050 Technical Manual Page 2 Table of Contents Table of Contents ...
GE1050 Technical Manual Page 20 Installing GigE Viewer for Testing o The latest Viewer software can be downloaded from http://www.alliedvisiontec.c
GE1050 Technical Manual Page 21 System Optimization o Open the Network Connections Dialog as follows: From the Windows desktop select start, then s
GE1050 Technical Manual Page 22 Figure 10. Network card advanced settings. o Set Maximum Frame Size or Jumbo Frames to the maximum possible value
GE1050 Technical Manual Page 23 Trouble Shooting Is the camera getting power? The right LED is the camera power indicator. If unlit, check the power
GE1050 Technical Manual Page 24 • Camera is not listed, or flashing “Camera Unavailable”: There may be multiple NICs on your system set to the sam
GE1050 Technical Manual Page 25 All stats 0 while streaming. Firewall likely blocking traffic • All stats 0. Likely a firewall is blocking incomin
GE1050 Technical Manual Page 26 Addendum
GE1050 Technical Manual Page 27 GE IO Schematic VDD-3.3LOGIC TXDISO+5VMAX3221CPWRMAXIM12345678 910111213141516ENC1+V+C1-C2+C2-V-RIN ROUTINVAL
GE1050 Technical Manual Page 28 Hirose 12-pin Trigger Schematic USER TRIGGER (5V TTL DRIVER)SYNC OUT 2ONE GROUNDRETURN IS SUFFICIENT.SYNC OUT
GE1050 Technical Manual Page 29 Mini-SMB Trigger Schematic OUTRG-174 COAX CABLETRIGGER INPUTINUSERS TRIGGER CIRCUITMINI-SMBMINI-SMBSYNC OUT 1
GE1050 Technical Manual Page 3 Legal notice For customers in the U.S.A. (FCC Compliance Information) This equipment has been tested and found
GE1050 Technical Manual Page 30 Trigger Timing Diagram User Trigger Logic Trigger Exposure Readout Trigger Ready Imaging Tpd Trigger Latency
GE1050 Technical Manual Page 31 Notes on Triggering Definitions o User Trigger is the trigger signal applied by the user. o Logic Trigger is the t
GE1050 Technical Manual Page 32 Triggering during the Readout State o For applications requiring the fastest triggering cycle time whereby the came
GE1050 Technical Manual Page 4 Contacting Allied Vision Technologies • Technical information: http://www.alliedvisiontec.com • Support: s
GE1050 Technical Manual Page 5 Introduction The GE1050 series of cameras are sensitive, 60 frames per second, 1 megapixel, Gigabit Ethernet cameras
GE1050 Technical Manual Page 6 Specifications Sensor Type Kodak KAI-01050 Sensor Shutter Type Progressive Interline Image Resolution 1024 x 102
GE1050 Technical Manual Page 7 Supported Features Imaging Modes free-running, external trigger, fixed rate, software trigger Fixed Rate Control 0
GE1050 Technical Manual Page 8 Mechanical Figure 1. GE SERIES mechanical dimensions.
GE1050 Technical Manual Page 9 Connections 1562347 Figure 2. GE SERIES connection diagram.
Comments to this Manuals